EI-35 low frequency linear power supply Voltage input according to national standards. Complete safety regulations. AC and DC output. The output voltage and current are variable, and the output plugs are diverse. Welcome to customize according to requirements. Output voltage: 1 5 -28 V AC and DC output Output current: 50-800 mA AC output Maximum power: 3 6W DC output Maximum power: 3 2W
Model : 351200200
Input voltage: AC fixed voltage input;
China 220VAC50Hz; Japan 100VAC50/60Hz; Taiwan 110VAC60Hz; USA/Canada 120V AC 60Hz; Korea: 220VAC60Hz; Europe: 230VAC50Hz; Australia New Zealand: 240VAC50Hz.
Input plug: Japan; Taiwan; the United States, Canada two flat plug. China mainland has two flat plugs (no holes). Europe 4.0 two round inserts. South Korea 4.8 two round inserts. Australia and New Zealand are eight characters outside. All are wall-mounted inputs.
Output voltage: 1.5 -28 V AC and DC output
Output current: 50-800 mA
AC output maximum power: 3.6W
DC output maximum power: 3.2W
Working temperature: 0 ° C ~ + 40 ° C
Storage temperature: -40 ° C ~ + 85 ° C
Relative humidity: 5% - 95%
Non-condensing load regulation: +/-5% change from minimum to maximum output current.
Insulation resistance: 500VDC power supply, minimum 1 million ohms between input and output plug and housing.
Pressure-resistant HI-POT test: PSE/UL: 1240V/min; GS/SAA/CCC/K-MARK: 3750V/min; that is, the AC voltage between the input and output plugs and the casing is continuously tested for 1 minute with the standard AC voltage. . (leakage current 2ma)
Inrush: up to 70 mA.
Average life expectancy: 100,000 hours, 100% load at 25 ° C ambient temperature.
Maximum temperature rise: 75 ° C, under the condition of 25 ° C, the maximum temperature of the surface of the outer casing shall not exceed 50 ° C by measuring the resistance of the primary coil under rated load conditions.
Electromagnetic compatibility EMI requirements: Meet and meet CE EN 55022:55024; FCC Part 15 Class B.
Safety certification: PSE / UL / CUL / GS / CE / SAA / K-MARK; IEC60950; EN61558; EN60950-1; UL1310; UL1950
Quality assurance: 5 years
RoHS compliant |